Discover the design, zone by zone
One lens. Every detail.
Follow the lens from centre to edge. Scroll to reveal each feature as the lens and its story move together.
For eye care professionals · Manufactured in Saudi Arabia
Your eye measurements. Our custom lens manufacturing. Work with VISIORA to turn corneal and scleral surface measurements from your clinic into a personalised OraSight Freeform scleral lens.
Acquire corneal and scleral measurements and identify the right and left eye clearly.
Contact VISIORA for the accepted export files and submission channel. Include the clinical prescription and relevant fitting requirements.
Our technical team reviews the measurements with your centre, confirms the design requirements and manufactures the custom OraSight lens.
Your practitioner evaluates the lens on the eye and follows the patient. Share fitting feedback with our team when further adjustments are needed.
We welcome OraSight manufacturing inquiries from eye care centres in Saudi Arabia and around the world. Tell us your country, device and clinical requirements; we confirm the ordering process, supply arrangements and lead time before proceeding.
Discover the design, zone by zone
Follow the lens from centre to edge. Scroll to reveal each feature as the lens and its story move together.
Optic-zone diameter and base curve are two distinct design dimensions. Watch the optic zone expand and contract as the Mid-peripheral and adjoining zones follow smoothly. Then compare steeper and flatter base curves at the same overall SAG.
Move the midperipheral and limbal boundaries independently. Two rings. Two distinct ways to shape the transition beyond the optic zone.
Raise or lower the landing together with its edge. Then refine the edge relative to that connected peripheral surface.
See the whole lens contract or expand. Explore overall diameter and sagittal depth as separate design dimensions.
Scroll through 0, 150, 300 and 500 microns. Watch the two principal meridians change at true scale before the next peripheral design appears.
Keep scrolling as the superior, temporal, nasal and inferior quadrants rise and lower in sequence. Their curves stay smoothly connected to neighbouring quadrants, the landing and the edge.
The quadrant surface blends into a continuous Freeform contour. Follow its changing peripheral shape while the landing and edge remain joined.
Follow a full ring, one quadrant, then a small angular sector. Watch the local elevation change without changing the entire circumference.
The optic zone can shift through all 360°: temporal, superior-temporal, superior, superior-nasal, nasal, inferior-nasal, inferior and inferior-temporal.
Explore sphere, cylinder and axis together. Rotate the cylinder axis in one-degree steps, and distinguish optical correction from landing toricity.
Follow Center-near, then Center-distance, as the centre diameter changes the optical zones.
Follow Center-near and Center-distance together with cylindrical correction and its axis. The optical Toric component is shown independently of landing toricity.
The initial shape is sampled from the supplied S02-L2-150 front/back files: overall diameter 15.00 mm, optic diameter 8.00 mm, back optic radius 8.23 mm, front optic radius 8.32036 mm and central thickness 0.30 mm. Back-file SAG header: 3.6839 mm, kept distinct from coordinate height.
Motion illustrates proposed customisation options. Zone boundaries, optical maps and changes are not manufacturing surfaces or a patient fit simulation. Height changes use the stated micron scale; transitions remain connected through the landing and rim. Toricity is illustrated separately in microns; it is not optical cylinder. Final parameters and availability are confirmed with the technical team.
We welcome OraSight manufacturing inquiries from eye care centres in Saudi Arabia and around the world. Tell us your country, device and clinical requirements; we confirm the ordering process, supply arrangements and lead time before proceeding.
Arrange measurement submissionMap the cornea and sclera using digital profilometry. Surface elevation data guides OraSight’s personalised Freeform design.
Use the map to shape the Landing Zone around the sclera. Refine limbal clearance, the lens edge and other zones for the case.
Customise the Optic Zone diameter and offset. Optical options include Front Toric and Multifocal Toric.
Fitting can start with a digital scan or with a trial lens on the eye. You can also design a trial set around the needs of your clinic.
| Parameter | Design options |
|---|---|
| Lens diameter | Customisable |
| Optic Zone | Custom diameter and offset |
| Base Curve | Steeper or flatter while maintaining overall Sag |
| Vault / Clearance | Central, Limbal and Mid-peripheral adjustment in µm |
| Landing Zone | Toric, Quadrant-specific or Freeform |
| Lens edge | Heel-toe Alignment and Edge Lift adjustment |
| Optics | Front Toric, Multifocal, Multifocal Toric and Prism |
| Multifocal centre | Center Near or Center Distance |
Design a trial lens for a specific case or build a custom trial set for your clinic.
| Lens marking | Sag at lens edge (µm) |
|---|---|
| L01-150 | 3970 |
| L02-150 | 4240 |
| L03-150 | 4540 |
| L04-150 | 4850 |
| L05-150 | 5100 |
| L06-150 | 5440 |
| L07-150 | 5750 |
In the lens marking, “150” denotes Toricity of 150 µm. Toricity can be customised to other values, including higher values, to suit your trial set.
All edge Sag values are defined for the flat meridian.
Freeform describes a design shaped around the individual eye’s surface rather than a single standard landing shape. Profilometry provides the surface information; the practitioner’s prescription and fitting requirements guide the lens design.
Yes. Centres outside Saudi Arabia can contact VISIORA with their country, device and requirements. Our team confirms the ordering and supply arrangements for that destination before starting the order.
Start by telling us which measurement device and software version you use. We will confirm the required measurement export files, supporting clinical information and transfer channel before you send case data.
No. The scan supports the custom design. A qualified practitioner still evaluates the manufactured lens on the eye and manages fitting and follow-up.
Clinical reference for eye care professionals
Use the eye shape to select an initial OraSight trial lens. Evaluate the fit on the eye after the lens settles, then refine each zone as needed.
Empirical Fit
Start with an empirical fit based on the measurements and shape of the eye.
AC Depth estimate
Convert AC Depth to microns, add 850 µm and select the closest Sag in the fitting reference. Edge Sag is the trial lens specification measured at the lens edge.
AC Depth and Kmax
Use the AC Depth and Kmax chart in the fitting reference to choose a starting trial lens. Confirm the selection on the eye after settling.
Fill the lens with preservative-free saline and fluorescein. Check for bubbles, Clearance and centration under diffuse blue light. Measure Apical Clearance using a slit-lamp optic section or OCT. After settling, if Central Clearance exceeds 500 µm, try a lower Sag and let the replacement lens settle for 10–15 minutes. If Clearance is below 50 µm or the lens touches the cornea, increase Sag by one or two trial steps.
Assess the Limbal Vault and look for compression or Edge Lift. Flatten the Landing Zone if there is conjunctival compression, resistance on removal or staining after removal. Steepen it if there is excessive Edge Lift, tear exchange or movement. Compare both meridians. The fitting guide suggests increasing Toricity when there is Edge Lift or tear exchange at the Steep Meridian with vessel blanching at the Flat Meridian, and decreasing it when these signs are reversed. Reassess the fit after adjustment.
OraSight supports GAUDI Profilometer and Eaglet Eye ESP measurement data for Freeform lens design. VISIORA confirms the file format and submission method.